Power Oscillations Damping Using UPFC

[Full Text]

 

AUTHOR(S)

K.Dhayalini, Kirthika.S, Merlin Diyana.S, Gayathri.D, Kalpana.K

 

KEYWORDS

Unified Power Flow Controller(UPFC), stabilization, Flexible AC Transmission System( FACTS), Power Oscillation Damping (POD

 

ABSTRACT

This paper uses a FACTS device, UPFC for damping power oscillation in transmission systems as the power oscillations might increase risk of instability in the system and may also reduce power quality when the power system is being exposed to any disturbance. FACTS controllers permit newer approaches to system stabilization. In the proposed system, whenever power oscillations are detected due to any system disturbance the UPFC provides voltage support and improves the power system stability. The proposed system improves damping performance when compared with other methods. Harmonics is reduced in this proposed system. The quicker power oscillation damping using UPFC ensures smooth and reliable flow of the power through transmission line. This paper implements the control scheme and result is thus obtained for oscillations damping using Unified Power Flow Controller (UPFC) based on the computer simulations using the MATLAB software.

 

REFERENCES

[1] Arabi.S,Hamadanizadeh.H,andFardanesh.B.B.(2002),“Convertible static compensator performance studies on the NY state transmission system”IEEE Trans. Power Systems, vol. 17, pp. 701-706.
[2] Bian.X.Y, Geng.Y, Lo.K.L, Fu.Y, and Zhou.Q.B.(2016), “Coordination of PSSs and SVC Damping Controller to Improve Probabilistic Small- Signal Stability of Power System With Wind Farm Integration”IEEE Trans. Power Systems, vol. 31.
[3] Dhayalini.K & Mukesh .R, 2017, Optimal tracing based real power loss in transmission lines published in IEEE Xplore Digital Library, pp: 20-25.
[4] Eftekharnejad.S, Vittal.V, Heydt.G.T, Keel.B, and Loehr.J.(2013), “Small Signal Stability Assessment of Power Systems With Increased Penetration of Photovoltaic Generation: A Case Study," IEEE Trans. Sustainable Energy, vol. 4, pp. 960-967.
[5] R. Manivasagam and V. Dharmalingam, "Power quality problem mitigation by unified power quality conditioner: An adaptive hysteresis control technique," International Journal of Power Electronics, vol. 6, pp. 403-425, 2014. Available at: https://doi.org/10.1504/ijpelec.2014.067442.
[6] Haque.M.(2004), “Improvement of first swing stability limit by utilizing full benefit of shunt FACTS devices”, IEEE Trans. Power Systems, pp. 1894-1902
[7] Dhayalini. K, 2017, ‘Hybrid Particle Swarm Optimization - Genetic Algorithm Based Optimal Dispatch of Wind and Thermal System, Asian Journal of Research in Social Sciences and Humanities, vol. 7, no.1, pp 364 -383.
[8] Hingorani.N.G and Gyugyi.L.(2000),”Understanding FACTS: concepts and technology of flexible AC transmission systems” Wiley-IEEE press.
[9] Kundur.P, Balu.N.J, and Lauby M.G.(1994), “Power system stability and control”, vol. 7: McGraw-hill New York.
[10] R. Manivasagam and D. Aarthi, "Design of UPFC using ten switch converter with switch reduction," International Journal for Scientific Research & Evelopment, vol. 5, pp. 490-493, 2017.
[11] Li.Y, Rehtanz.C, Ruberg.S, Luo.L, and Cao.Y.(2012), “Wide-Area Robust Coordination Approach of HVDC and FACTS Controllers for Damping Multiple Interarea Oscillations” IEEE Trans. Pwr Del., p1096-1105.
[12] Mathur.R.M and Varma.R.K.(2002),“Thyristor-based FACTS controllers for electrical transmission systems”John Wiley & Sons.
[13] Dhayalini. K, 2016, Optimization Of Wind-Thermal Coordination Dispatch Using Flower Pollination Algorithm, International Journal of Advancement in Chemistry, vol. 12, no.16, pp. 4963 – 4970.
[14] Mithulananthan.N, Canizares.C.A, Reeve.J, and Rogers.C.J.(2003), "Comparison of PSS, SVC, and STATCOM controllers for damping power system oscillations," IEEE Trans. Power Systems, pp. 786-792.
[15] Morjaria.M, Anichkov.D, Chadliev.V, and Soni.S.(2014), “A Grid- Friendly Plant: The Role of Utility-Scale Photovoltaic Plants in Grid Stability and Reliability" IEEE Power and Energy Magazine, vol. 12, pp. 87-95.
[16] R.Manivasagam & D Aarthi “Design and Implementation of UPFC Using Ten Switch Converter With Switch Reduction”, International Journal Of Engineering And Computer Science, vol.6,Issue.6, 2017 ,Page no. 21861-
21869.
[17] Padiyar.K.R and Varma.R.K.(1991), “Damping torque analysis of static VAR system controllers” IEEE Trans. Power Systems, vol. 6, pp. 458-465, 1991.
[18] Raghavi, R ,Manivasagam.R, “Modeling of a Grid Connected New Energy Vehicle Charging Station” International Journal of Applied Engineering
Research (IJAER), Volume 10, Number 20 (2015), Special Issues, pp. 15870- 15875.
[19] Sanchez-GascaJ.J.(1998),“Coordinated Control of Two FACTS Devices for Damping Inter-Area Oscillations,” IEEE Trans.Power Sys., Vol. 13, No. 2, pp. 428–434.
[20] R. Manivasagam, P. Parthasarathy, and R. Anbumozhi, "Robust analysis of T-S fuzzy controller for nonlinear system using H-infinity," Advances in Intelligent Systems and Computing, vol. 949, pp. 643-651, 2019. Available at: https://doi.org/10.1007/978-981-13-8196-6_56.
[21] Simoes.A.M, Savelli.D.C, Pellanda.P.C, Martins.N, and Apkarian.P.(2009), “Robust design of a TCSC oscillation damping controller in a weak 500-kV interconnection considering multiple power flow scenarios and external disturbances," IEEE Trans. power systems, vol. 24, pp. 226-236.
[22] Tamimi.B, Canizares.C, and Bhattacharya.K.(2013), “System stability impact of large-scale and distributed solar photovoltaic generation: the case of Ontario, Canada," IEEE Trans. Sust. Energy, vol. 4, pp. 680-688.
[23] Tiba.C and Ricardo.E.D.(2012), “Siting PV plant focusing on the effect of local climate variables on electric energy production–Case study for araipina recife,” Renewable energy,vol 48
[24] Varma.R.K, Khadkikar.V, and Seethapathy.R, “Nighttime Application of PV Solar Farm as STATCOM to Regulate Grid Voltage," IEEE Trans. Energy Conversion, vol. 24, pp. 983-985, 2009.
[25] Xiao.Y, Song.Y, Liu.C, and Sun.Y.(2003),“Available transfer capability enhancement using FACTS devices” IEEE Trans. Power systems,vol.18.