Compressor Load Analysis Of Air Blast Freezer (ABF) Design For Capacity Of 250 Kg

[Full Text]

 

AUTHOR(S)

Syawaluddin, Anwar Ilmar Ramadhan, Ery Diniardi, Erwin Dermawan

 

KEYWORDS

Air Blast Freezer (ABF), load, compressor

 

ABSTRACT

In this study Air Blast Freezer (ABF) to freeze 250kg of bread dough in 1 hour with the amount of space ABF requested as much as 2 room. The purpose of the research is to select the required compressor ABF with the calculation of the load obtained. The condition of each room has a heat load of 41.5 kW with target room temperature -35̊C. The result is total compressor capacity 58.2 kW x 2 compressor or 116.4 kW, while the calculation load according to condition of end of room ABF is equal to 37.81 kW x 2 room or equal to 75.62 kW , 40.78 kW difference, or enough to make one more ABF room with the same design and capacity.

 

REFERENCES

[1] Anonim, Teknik Refrigerasi dan Tata Udara, Politeknik Negeri Bandung, Bandung (in Indonesian)

[2] Food Review, 2007, Teknik Pembekuan Pangan, Indonesia (in Indonesian)

[3] Dempsey, P., & Bansal, P., 2012, the art of air blast freezing: Design and efficiency considerations. Applied Thermal Engineering, 41, 71-83.

[4] Nofrizal, 2008, Perancangan Thermal dan Elektrikal, Fakultas Teknik Universitas Indonesia, Jakarta (in Indonesian)

[5] Naik, J., et al., 2010, Quality Changes During Freezing and Frozen Storage of Mackerel (Rastrelliger Kanaguria) and Pink Perch (Nemipterus Japonicus) in Summer Season, Environment and Ecology, 28(4): 2396-2400

[6] Dermawan, E., Syawaluddin, Abrori, M. R.,Nelfiyanti Nelfiyanti, Ramadhan, A. I., 2017, Analisa Perhitungan Beban Kalor Dan Pemilihan Kompresor Dalam Perancangan Air Blast Freezer Untuk Membekukan Adonan Roti, Teknika : Engineering and Sains Journal, Vol 1 No 2 (in Indonesian)

[7] Pesulima, W., Ningsih, O., 2013, Evaluation and Implementation HACCP of Frozen Tuna Saku, The 1st International Symposium on Aquatic Product Processing 2013

[8] Rahmat, M. F., 2015, Perancangan Cold Storage Untuk Produk Reagen, Bekasi (in Indonesian)