Experimental Study Of Composite Connections For Cold-Formed Steel Using Isolated Joint Test

[Full Text]

 

AUTHOR(S)

Muhammad Firdaus, Anis Saggaff, Mahmood Md Tahir, Shek Poi Ngian, KM Aminuddin, Saloma

 

KEYWORDS

Cold-formed steel, composite beam, gusset plate, moment resistance

 

ABSTRACT

Cold-formed research that has been studied, which still focused on the capacity of beam and column components. Nonetheless, there is still a lack of data and knowledge on the composite construction behavior, and the performance of CFS Composite beam advantages such as strength and cheapness have led to the dominance of composite beam in the commercial building. The purpose of this study is to investigate the failure modes that occur and present the results of the strength and stiffness of the gusset plate connection of the composite structure. This study uses one type of connection made in the form of cantilever beams whose floor plates use concrete cast with metal decking. The shear connector used uses M12 grade 8.8 bolts with the same tensile stress as the other bolt connections. Beams and columns use cold-formed steel with a thickness of 2.4 mm with a DLC200 size for the beam and a DLC300 size for the columns. The connection uses a hot-rolled steel type gusset plate with a thickness of 6 mm. This failure mode can be indicated that there is an influence of the sliding bolt resistance and bolt support on the joint resistance. Deformation also occurs on a concrete plate that occurs at a distance of 100 mm from the face of the column flange The recording results show the ultimate load achieved is 31.6 kN with 62.26 mm deflection. The ultimate moment occurs is 31.6 kNm with a rotation of 0.038 rad, and the stiffness experiment is 730 kNm/rad. The ratio of the moment experimental with analytical calculations showing a good agreement of 1.41. The ratio between other study has 0.50 ratio of moment resistance and 0.46 for stiffness

 

REFERENCES

[1] J. Ye, I. Hajirasouliha, and J. Becque, "Cold-formed steel channel beams: From optimal design to development of a novel section," in The Annual Postgraduate research Student Conference-2015, 2015.
[2] T. M. Alhajri et al., "Behavior of pre-cast U-Shaped Composite Beam integrating cold-formed steel with ferro-cement slab," Thin-Walled Structures, vol. 102, pp. 18-29, 2016.
[3] C.-T. T. Hsu, S. Punurai, W. Punurai, and Y. Majdi, "New composite beams having cold-formed steel joists and concrete slab," Engineering Structures, vol. 71, pp. 187-200, 2014.
[4] K. Alenezi, M. M. Tahir, T. Alhajri, M. R. K. Badr, and J. Mirza, "Behavior of shear connectors in composite column of cold-formed steel with lipped C-channel assembled with ferro-cement jacket," Construction and Building Materials, vol. 84, pp. 39-45, 2015.
[5] C. S. Tan, M. M. Tahir, P. N. Shek, and A. B. H. Kueh, "Experimental Investigation on Slip-In Connection for Cold-Formed Steel Double Channel Sections," Advanced Materials Research, vol. 250-253, pp. 1038-1041, 2011.
[6] K. Aminuddin, A. Saggaff, and M. M. Tahir, "Experimental behaviour of beam-column connection using cold-formed steel sections with rectangular gusset-plate," in AIP Conference Proceedings, 2017, vol. 1903, no. 1, p. 020006, U: AIP Publishing.
[7] K. Aminuddin, A. Saggaff, and M. M. Tahir, "Structural Behaviour Of Slip-In Gusset Plate Connection For Double Lipped Channel Cold Formed Steel Using Partial Strength Connection."
[8] H. Ahamed and M. Mahendran, "Bolted beam-column moment connections between cold-formed steel members," in 21st Australasian Conference on the Mechanics of Structures and Materials (ACMSM 21), 2010.
[9] Y. H. Lee, C. S. Tan, S. Mohammad, and Y. L. Lee, "Mechanical Properties Prediction for Cold-formed Steel Angle Connection with Various Flange Cleat Thickness," JURNAL TEKNOLOGI, vol. 74, no. 4, pp. 51-59, 2015.
[10] Ž. Bučmys and A. Daniūnas, "Analytical and experimental investigation of cold-formed steel beam-to-column bolted gusset-plate joints," Journal of Civil Engineering and Management, vol. 21, no. 8, pp. 1061-1069, 2015.
[11] A. Saggaff, T. Alhajri, M. Ismail, K. Alenezi, and M. Ragae, "Finite Element Modelling of Innovative Precast Cold-Formed Steel Ferrocement as Composite Beam," Applied Mechanics and Materials, vol. 752-753, pp. 539-543, 2015.
[12] BS EN 1993-1-8:2005 - Eurocode 3: Design of steel structures . Part 1-8: Design of joints, 2005.
[13] BS EN 1993-1-3:2006 - Eurocode 3 : Design of steel structures : Part 1-3: General rules : Supplementary rules for cold-formed members and sheeting, 2006.